MIL-DTL-82112C(MC)
Testing shall be performed on components listed in Table II for
characteristics noted.
TABLE II.
Test methods.
Reqmt.
Test
No. det.
Results
Components
Characteristics
method
per S/unit
reported as
para.
Crinoline
Material
3.3.4.1
1200
Pass or fail
identification
Weight
3.3.4.1
5041
Pass or fail
Thread count
3.3.4.1
Visual
Pass or fail
Breaking strength
3.3.4.1
5100
Pass or fail
Color
3.3.4.1
Visual
Pass or fail
Underlay
Color
3.3.4.2
Visual
Pass or fail
Flexibility
3.3.4.2
5230
Pass or fail
4.4.1.1. Sampling for testing. Unless otherwise specified in
subsidiary specifications, sampling shall be in accordance with
the following. The lot shall be unacceptable if one or more
sample units fail to meet any test requirements specified herein.
Lot size
Sample size
2
800 or less
801 to 22,000 inclusive
3
22,001 and over
5
The unit for expressing lot size and sample unit for testing each
component shall be in accordance with the applicable subsidiary
specifications and as follows:
Component
Expressed as
Sample unit for testing
Crinoline
yards
one yard full width
Underlay
yards
one yard
4.4.2 In-process inspection. Inspection shall be performed
during the manufacturing of the end item to ascertain the
operations are performed as specified herein. The Government
reserves the right to determine the acceptability of construction
methods not performed in accordance with specified requirements
for operations or subassemblies.
9